Configuration
CPU 317T: Technology Functions
4-42 A5E00251798-03
4.5.6.4 Dynamic response
In the "Dynamic response" tab of the Axis > Limits dialog box, you can adjust the
HW limits (mechanical) and the SW limits.
The set deceleration limit comes into effect when a moving axis is disabled and,
and MC_Power FastStop = 1.
The status-based acceleration model is enabled (default) by setting the "Absolute
values" check box.
The direction-based acceleration model is enabled by resetting the "Absolute
values" check box. In this case, additional parameters are displayed.
Status-dependent acceleration
Acceleration
Axis acceleration, irrespective of the direction.
Deceleration
Axis deceleration, irrespective of the direction.