Connect Tech JB1 Bedienungsanleitung Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
22 RS-232/RS-422/485 Option
Multi-drop Slave Mode
By placing a jumper on position A of jumper blocks JB4, JB5,
JB6, JB7 and on J1 (ports 1 & 2) or J2 (ports3 & 4) you can run
the individual RS-422/485 ports in multi-drop slave mode. In this
mode the TxD line driver is enabled only when data is transmitted
and RxD is enabled all the time. This mode is typically used in
multi-drop "4 wire" connections.
Figures 1 and 2 show the locations of jumper block JB4, JB5,
JB6, JB7 and J1, J2.
Example
The example below shows the settings on JB4, JB5, JB6, JB7 and J1,
J2 where RS-422/485 ports 1, 2 are set for multi-drop slave mode.
Ports 3, 4 are RS-232 and therefore should not be set for multi-drop
slave mode.
JB4
JB5
JB6
JB7
J1
Jumper is
on J1
J2
Jumper is
off J2
A
B
C
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
Note: Rev A & B Xtreme/104 Opto adapters do not have
positions H & I on jumper blocks, JB4, JB5, JB6, and JB7
Jumper Legend
(Rev. C & later adapters)
A = TxD control
B = RS-232/RS-422/485 select
C = RxD control
D = RTS terminator
E = TxD terminator
F = RxD terminator & bias
G = RxD terminator & bias
H = CTS terminator & bias
I = CTS terminator & bias
Jumper Legend
(Rev. A & B adapters)
A = TxD control
B = RS-232/RS-422/485 select
C = RxD control
D = RTS terminator
E = TxD terminator
F = CTS terminator
G = RxD terminator
Technical Tip:
J1 controls ports 1 and 2 and J2 controls ports 3 and 4. If both ports
1 and 2 are set for full duplex then you should not jumper J1. If both
ports 3 and 4 are set for full duplex then you should not jumper J2.